Measurements Lucy AMT 21

Measurements Lucy AMT 21
Here you can find the measurements for the kit Lucy AMT 21.
 
The measurements are made with the Clio FW measurement system from Audiomatica
 
The measuring amplifier is a Clio QC-Box 5. This control unit performs a variety of tasks, e.g. controlling a laser, controlling turntables, etc.
 
For the measurements a calibrated Audiomatica Mic-01 with a length of 25 cm is used.

Frequency response

 

Measurements Lucy AMT 21, Frequency response

Frequency response measured at 0°, 15°, 30° and 45° angle

Measurements Lucy AMT 21, Frequency response measured at 0°, 15°, 30° and 45° angle

Frequency response of the individual paths (for each driver)

Measurements Lucy AMT 21, Frequency response of the individual paths (for each driver)

Waterfall spectrum

 

Measurements Lucy AMT 21, Waterfall spectrum

Distortion over frequency at 85 dB sound pressure level

Measurements Lucy AMT 21, Distortion over frequency at 85 dB sound pressure level

Distortion over frequency at 95 dB sound pressure level

Measurements Lucy AMT 21, Distortion over frequency at 95 dB sound pressure level

Impedance frequency response

 

Measurements Lucy AMT 21, Impedance frequency response

Frequency response of the tweeter

Measurements Lucy AMT 21, Frequency response of the tweeter

Frequency response of the tweeter with bypass capacitor

Measurements Lucy AMT 21, Frequency response of the tweeter with bypass capacitor

Frequency response of the tweeter with trap circuit

Measurements Lucy AMT 21, Frequency response of the tweeter with trap circuit

Frequency response of the woofer

Measurements Lucy AMT 21, Frequency response of the woofer

Frequency response of the woofer with trap circuit

Measurements Lucy AMT 21, Frequency response of the woofer with trap circuit

For questions and more information please call us: +49 721 970 37 24

You can also send us an email: info@lautsprechershop.de


to the assembly kit Lucy AMT 21