Measurements Spica Wall 2

Here you can find the measurements for the kit Spica Wall 2.

The measurements are made with the Clio FW measurement system from Audiomatica

The measuring amplifier is a Clio QC-Box 5. This control unit performs a variety of tasks, e.g. controlling a laser, controlling turntables, etc.

For the measurements a calibrated Audiomatica Mic-01 with a length of 25 cm is used.
 

Frequency response

Frequency response measured at 0°, 15° and 30° angle

  • Blue = 0°
  • Green = 15°
  • Red = 30°

 

Frequency response of the individual paths (for each driver)

  • Blue = Sum of tweeter and woofer measured on axis
  • Green = high frequency branch
  • Red = low frequency branch

 

Waterfall spectrum

Distortion over frequency at 85 dB sound pressure level

  • Blue = k2
  • Red = k3
  • Green = k5


 

Distortion over frequency at 95 dB sound pressure level

  • Blue = k2
  • Red = k3
  • Green = k5


 

Impedance frequency response

  • Blue = without impedance correction
  • Red = with impedance correction


 

Frequency response of the tweeter

  • Blue = with crossover
  • Orange = without crossover


 

Frequency response of the tweeter with bypass capacitor

  • Blue = with capacitor
  • Orange = without capacitor


 

Frequency response of the woofer

  • Blue = with crossover
  • Orange = without crossover


 

Frequency response of the woofer with trap circuit

  • Blue = with trap circuit
  • Orange = without trap circuit

For questions and more information please call us: +49 721 970 37 24

You can also send us an email: info@lautsprechershop.de
 


to the assembly kit Spica Wall 2